OCCUPATION AND HEALTH ›› 2025, Vol. 41 ›› Issue (14): 1873-1877.

• Treatise •     Next Articles

Sampling survey on radiation dose and influencing factors of CT examinees in Dalian

LIU Shuang1, ZHANG Xinghui1, YANG Xianwu2, NI Changyu1, AI Qi3, DONG Lei3   

  1. 1. Department of Occupational Radiation Health,Dalian Center for Disease Control and Prevention,Dalian,Liaoning 116033,China;
    2. Dalian Health Supervision Center,Radiological Health Supervision Department,Dalian,Liaoning 116012,China;
    3. Department of Radiology,Dalian University Affiliated Xinhua Hospital,Dalian,Liaoning 116001,China
  • Received:2024-11-05 Revised:2024-11-26 Online:2025-07-15 Published:2025-12-12

Abstract: Objective To investigate the radiation dose of some computed tomography(CT) scan patientsin Dalian,analyze the influencing factors,optimize the radiation dose,and better guide radiation hygiene work. Methods The dose reports of head,chest and abdomen of 2505 CT subjects from 9 medical institutions in Dalian were reviewed and classified into 5 groups of 0-<1,1-<5, 5-<10,10-<18 and 18-<70 years.The CT scanning parameters,volume CT dose index(CTDIvol) and dose length product(DLP) were recorded,andthe results were compared and analyzed with domestic and international reference data. Results The P75 percentile of head,chest and abdominal DLP of adult CT subjects(848,444,683 mGy·cm) were all below the diagnostic reference level(DRL) in China. For children across four age groups,the P75 percentile of head DLP of CT subjects were 513,623,674,728 mGy·cm,respectively,the P75 percentile of chest DLP were 50,87,138,280 mGy·cm,respectively,the P75 percentile of abdominal DLP were 121,130,150,211 mGy·cm,respectively,. There was no statistically significant difference in head exposure among CT subjects at 5different age groups(χ2=7.123,P>0.05),while there were statistically significant differences in chest and abdominal exposure(χ2=128.162,25.401,both P<0.05).The radiation doses for adult CT examinees in hospitals at all levels were generally below the DRL,but the head radiation doses in county-level hospitals and abdominal radiation doses in provincial hospitals were higher. Conclusion The radiation dose of CT examinees investigated in this study was basically lower than the DRL in China,but compared with the values reported in other regions,some of the values were higher. There is still room for dose optimization. It is recommended that medical institutions conduct regular training and assessment of CT radiation dose,set up personalized scanning parameters to optimize the radiation dose. Health administrative departments should strengthen the supervision and management of radiation protection and actively establish regional DRL.

Key words: Computed tomography, Radiation, Dose, Volume CT dose index, Dose length product, Influencing factors, Sampling

CLC Number: