职业与健康 ›› 2026, Vol. 42 ›› Issue (16): 2199-2203.

• • 上一篇    下一篇

微波消解-全谱直读电感耦合等离子体发射光谱法测定特殊医疗污水中12种元素

朱华婷1,2, 连玉龙1()   

  1. 1 南通大学公共卫生学院江苏 南通 210003
    2 苏州工业园区疾病防治中心有限公司江苏 苏州 215000
  • 收稿日期:2025-08-20 修回日期:2025-10-25 出版日期:2026-08-15 发布日期:2026-08-10
  • 通信作者: 连玉龙,E-mail:1003412478@qq.com
  • 作者简介:朱华婷,女,副主任技师,主要从事检测统计分析工作。
  • 基金资助:
    江苏省自然科学基金(BK20211331)

Determination of 12 elements in special medical wastewater by microwave digestion and full-spectrum direct-reading inductively coupled plasma atomic emission spectrometry

ZHU Huating1,2, LIAN Yulong1()   

  1. 1 School of Public HealthNantong University,NantongJiangsu 210003, China
    2 Suzhou Industrial Park Center for Disease Prevention and Control Co.Ltd.,SuzhouJiangsu 215000, China
  • Received:2025-08-20 Revised:2025-10-25 Online:2026-08-15 Published:2026-08-10
  • Contact: LIAN Yulong,E-mail:1003412478@qq.com

摘要:

目的 建立特殊医疗污水中12种元素砷(As)、银(Ag)、镉(Cd)、钛(Ti)、镍(Ni)、磷(P)、铬(Cr)、硒(Se)、铍(Be)、铅(Pb)、钒(V)和钡(Ba)的微波消解-电感耦合等离子体发射光谱(inductively coupled plasma - atomic emission spectroscopy,ICP-AES)的测定方法。方法 特殊医疗污水经HNO3-H2O2体系微波消解,优化仪器关键参数后使用ICP-AES方法测定12种元素含量,同时利用回收率试验、重复测试来验证方法的准确性和可靠性,并对12家医疗机构的48份污水样本进行检测分析。结果 该方法在0.10~3.00 mg/L浓度范围内线性良好,相关系数(r)为0.999 1~0.999 9,检出限为0.4~30.2 μg/L,相对标准偏差(RSD)为0.413%~4.476%,加标回收率91.0%~103.4%。46份污水样品检出钡(0.014~0.512 mg/L)和磷(0.768~6.750 mg/L),8份污水样品检出钛(0.006~0.039 mg/L),3份污水样品检出总砷(0.016~0.073 mg/L),其余8种元素的测定结果均小于各自方法检出限。结论 采用HNO3-H2O2消解体系,试样处理简便,该方法准确性好、灵敏度高、污染小,可用于批量医疗污水中多种元素快速同时测定。

关键词: 医疗污水, 元素, 微波消解, 电感耦合等离子体发射光谱

Abstract:

Objective To establish a method for the determination of 12 elements in special medical wastewater,including arsenic (As),silver(Ag),cadmium(Cd),titanium(Ti),nickel(Ni),phosphorus(P),chromium(Cr),selenium(Se),berylliu(Be),lead(Pb),vanadium(V),and barium(Ba),using microwave digestion-inductively coupled plasma-atomic emission spectroscopy(ICP-AES). Methods The special medical wastewater was digested using HNO3-H2O2 system under microwave irradiation. After optimizing the key parameters of the instrument,the ICP-AES method was used to determine the concentrations of the 12 elements. The accuracy and reliability of the method were verified by recovery experiments and repeated tests. A total of 48 wastewater samples from 12 medical institutions were detected and analyzed. Results The method showed good linearity in the concentration range of 0.10-3.00 mg/L,with correlation coefficients(r) ranging from 0.999 1 to 0.999 9. The detection limits were between 0.4 and 30.2 μg/L,the relative standard deviations(RSD) were between 0.413% and 4.476%,and the spiked recoveries were between 91.0% and 103.4%. In the 46 wastewater samples,barium(0.014-0.512 mg/L) and phosphorus(0.768-6.750 mg/L) were detected. Titanium(0.006-0.039 mg/L) was found in 8 samples,and total arsenic(0.016-0.073 mg/L) was detected in 3 samples. The determination results of the remaining eight elements were all below their respective method detection limits. Conclusion The use of the HNO3-H2O2 digestion system simplifies sample processing.The method is accurate,sensitive,and environmentally friendly,making it suitable for the rapid and simultaneous determination of multiple elements in batches of medical wastewater.

Key words: Medical wastewater, Elements, Microwave digestion, Inductively coupled plasma atomic emission spectrometry

中图分类号: