职业与健康 ›› 2025, Vol. 41 ›› Issue (10): 1340-1345.

• 论著 • 上一篇    下一篇

血样中20种元素的直接稀释ICP-MS法

蔡小璇ab, 李思燕ab, 马争b, 熊劲光b, 陈满连b, 陈惠鹏b   

  1. 东莞市第六人民医院 a职业卫生检测科, b东莞市职业卫生检测重点实验室,广东 东莞 523008
  • 收稿日期:2024-08-30 修回日期:2024-09-18 出版日期:2025-05-15 发布日期:2025-12-18
  • 作者简介:蔡小璇,女,主任技师,主要从事职业卫生检测与评价工作。
  • 基金资助:
    东莞市社会发展科技项目(20231800904091); 东莞市社会发展科技项目(20231800935812); 东莞市社会科技发展项目(20221800901552)

Determination of 20 elements in blood by ICP-MS with directly dilution

CAI Xiaoxuanab, LI Siyanab, MA Zhengb, XIONG Jinguangb, CHEN Manlianb, CHEN Huipengb   

  1. a Occupational Health Testing Department,b Dongguan Key Laboratory for Occupational Health Testing,Dongguan Sixth People's Hospital,Dongguan,Guangdong 523008,China
  • Received:2024-08-30 Revised:2024-09-18 Online:2025-05-15 Published:2025-12-18

摘要: 目的 建立应用基体改进剂直接稀释血样测定血中20种元素的电感耦合等离子体质谱(inductively coupled plasma-mass spectrometry,ICP-MS)方法,并应用于普通人群、职业人群及中毒人群的检测。方法 将血样用0.50%硝酸(HNO3)-0.10%曲拉通-100进行20倍稀释,应用正常人混合血加入不同浓度的混合标准溶液配制标准序列,使用10 μg/L钇(Y)、镥(Lu)内标溶液同时进样。应用内标校正法使用标准(standard,STD)和动能歧视(kinetic energy discrimination,KED)2种模式ICP-MS法测定。结果 20种元素在0.100~100.000 μg/L的线性范围内,线性关系均≥0.999。方法的检出限为0.001~0.096 μg/L,定量下限为0.003~0.320 μg/L。批内和批间相对标准偏差(relative standard deviation,RSD)分别为0.4%~4.6%和1.5%~4.9%,加标回收率为80.9%~111.2%。结论 该方法操作简单、快速、回收率高、重现性好、实用性强,适合普通人群、职业人群及中毒人群血样中20种元素的检测,为血液金属组学分析提供了新方法。

关键词: 基体改进剂, 直接稀释法, 电感耦合等离子体质谱, 血液样品, 元素

Abstract: Objective To establish a determination method by inductively coupled plasma-mass spectrometry(ICP-MS) for 20 elements in blood which was direct diluted with matrix modifier,and apply in the detection of the general population,occupational population,and poisoned population. Methods The blood samples were diluted 20-fold with 0.50% nitric acid(HNO3)-0.10% Triton X-100. The mixed normal human blood was added with different concentrations of mixed standard solution to prepare standard sequences. The internal standard solution of yttrium(Y) and lutetium(Lu) at the concentration of 10 μg/L was simultaneously injected.ICP-MS with standard(STD) and kinetic energy discrimination(KED) mode was used to determine the content of the samples by internal standard correction method. Results In the linear range of 0.100-100.000 μg/L,the linear relationship of the 20 elements was ≥0.999. The limit of detection was 0.001-0.096 μg/L and the lower limit of quantitation was 0.003-0.320 μg/L. The relative standard deviation(RSD) within and between batches was 0.4%-4.6% and 1.5%-4.9%,respectively.The recovery rate was 80.9%-111.2%. Conclusion This method is easy to operate,fast,with high recovery rate,good reproducibility and strong practicality,it is suitable for the detection of 20 elements in blood samples of the general population,occupational population and poisoned population,providing a new method for blood metabolomics analysis.

Key words: Matrix modifier, Direct dilution method, Inductively coupled plasma-mass spectrometry, Blood sample, Element

中图分类号: