职业与健康 ›› 2023, Vol. 39 ›› Issue (23): 3180-3183.

• 论著 • 上一篇    下一篇

重庆市核医学工作人员内照射剂量监测

吴梦云, 张华东, 李奎   

  1. 重庆市疾病预防控制中心职业与放射卫生所放射检验科,重庆 400042
  • 收稿日期:2023-04-25 修回日期:2023-06-13 出版日期:2023-12-01 发布日期:2026-03-26
  • 通信作者: 李奎,助理工程师,E-mail:wumycdc@163.com
  • 作者简介:吴梦云,女,主管技师,主要从事放射卫生工作。
  • 基金资助:
    重庆市自然科学基金(CSTB2022NSCQ-MSX1220); 重庆市科卫联合医学科研项目(2022QNXM030,2022 ZDXM034)

Internal radiation dose monitoring of nuclear medicine workers in Chongqing

WU Mengyun, ZHANG Huadong, LI Kui   

  1. Department of Radiology Laboratory,Institute of Occupational Health and Radiological Health,Chongqing Center for Disease Control and Prevention,Chongqing 400042,China
  • Received:2023-04-25 Revised:2023-06-13 Online:2023-12-01 Published:2026-03-26
  • Contact: LI Kui,Assistant engineer,E-mail:wumycdc@163.com

摘要: 目的 调查重庆市核医学开展情况,摸底核医学放射工作人员数量,对辖区内从事碘-131(131I)治疗的放射工作人员开展内照射剂量监测。方法 2021年使用甲状腺内照射碘测量仪,监测重庆市碘治疗全部工作人员甲状腺131I 活度、甲状腺待积器官剂量;根据被监测者工作情况,估算年待积有效剂量。结果 重庆市共计14家医院89名碘治疗工作人员,甲状腺中检出131I为36名,检出率40.4%,甲状腺中131I 活度在2.65~925.02 Bq,平均活度为(85.66±176.93)Bq;甲状腺待积器官剂量活度在0.18~62.11 μSv,平均剂量为(6.64±12.21)μSv;年待积有效剂量范围为0.01~3.11 mSv,平均剂量为(0.29±0.59)mSv。Logistic回归分析发现,技师岗位为年待积有效剂量的危险因素(P<0.05)。结论 重庆市部分医院人员与环境131I检出率都较高,辖区内核医学碘治疗工作人员年待积有效剂量有4名超过1 mSv。应加强工作场所和个人放射防护,提高放射工作人员辐射防护意识。

关键词: 核医学, 131I, 内照射

Abstract: Objective To investigate the development of nuclear medicine in Chongqing,determine the number of nuclear medicine radiation workers,and conduct internal radiation dose monitoring for radiation workers engaged in iodine-131(131I) therapy within the jurisdiction. Methods In 2021,the iodine measuring instrument for thyroid internal irradiation was used to monitor the thyroid 131I activity and thyroid organ dose of all iodine treatment workers in Chongqing. Based on the work situation of the monitored person,the annual accumulated effective dose was estimated. Results There were a total of 89 iodine treatment workers from 14 hospitals in Chongqing,of whom 36 had detected 131I in the thyroid gland,with a detection rate of 40.4%. The activity of 131I in the thyroid gland was 2.65-925.02 Bq,with an average activity of(85.66±176.93)Bq. The dose activity of thyroid organs to be accumulated was 0.18-62.11 μSv,with an average dose of(6.64±12.21)μSv. The annual effective dosage range was 0.01-3.11 mSv,with an average dose of (0.29±0.59)mSv. Logistic regression analysis showed that technician position was the risk factor for the annual accumulated effective dose(P<0.05). Conclusions The detection rate of 131I in personnel and environment of some hospitals in Chongqing is relatively high,with 4 medical iodine treatment workers in the jurisdiction receiving an annual effective dose exceeding 1 mSv. Workplace and personal radiation protection should be strengthened to enhance radiation protection awareness among radiation workers.

Key words: Nuclear medicine, 131I, Internal radiation