职业与健康 ›› 2025, Vol. 41 ›› Issue (15): 2017-2021.

• 论著 •    下一篇

江门市某磁性材料制造企业职业危害现状及关键控制点分析

刘静文, 梁丽红, 雷森   

  1. 江门市职业病防治所监护检查科,广东 江门 529000
  • 收稿日期:2024-12-06 修回日期:2024-12-18 出版日期:2025-08-15 发布日期:2025-12-12
  • 作者简介:刘静文,女,主管医师,主要从事职业卫生工作。

Analysis of occupational hazards status and HACCP in a magnetic material manufacturing enterprise in Jiangmen City

LIU Jingwen, LIANG Lihong, LEI Sen   

  1. Department of Guardianship and Inspection, Jiangmen Occupational Disease Control Institute, Jiangmen, Guangdong 529000, China
  • Received:2024-12-06 Revised:2024-12-18 Online:2025-08-15 Published:2025-12-12

摘要: 目的 了解江门市某磁性材料制造企业职业危害现状,分析生产过程中危害因素对劳动者的影响及危害程度,找出关键控制点,为减少劳动者职业病和职业性病损的发生提供参考依据。方法 根据该企业提供的2022—2023年职业病危害因素检测报告做好职业卫生学调查,确定评价指标,根据超标的危害因素,选取2022—2023年在江门市职业病防治所进行职业健康检查的271名在岗员工为研究对象,对职业健康检查资料进行分析。结果 该企业噪声检测点超标率为43.86%,其他检测指标均符合国家职业接触限值要求;纯音测听异常率为60.15%,其中男性与女性听力异常率差异有统计学意义(χ2=15.020,P<0.01),男性不同工龄间的听力异常率差异有统计学意义(χ2=14.139,P<0.01),女性不同工龄间的听力异常率差异无统计学意义(χ2=4.959,P>0.05)。男性接触不同噪声强度的听力异常率差异无统计学意义(χ2=0.047,P>0.05),女性接触不同噪声强度的听力异常率差异有统计学意义(χ2=5.227,P<0.05),不同岗位听力异常率差异有统计学意义(χ2=16.098,P<0.01),单纯接噪组和接触噪声粉尘组听力异常率差异有统计学意义(χ2=7.540,P<0.01)。结论 该磁性材料制造企业工作场所卫生学状况及噪声作业工人健康检查状况不容乐观,需找出关键控制点并采取措施,为该行业工人的健康保驾护航。

关键词: 磁性材料制造, 噪声, 危害现状, 关键控制点

Abstract: Objective To understand the current situation of occupational hazards in a magnetic material manufacturing enterprise in Jiangmen City,analyze the impact and degree of hazards on workers in the production process,identify the hazard analysis and critical control point(HACCP),and provide reference for reducing the occurrence of occupational diseases and injuries among workers. Methods According to the occupational disease hazard factor testing report provided by the enterprise from 2022 to 2023,conduct occupational hygienic investigation,determine evaluation indicators,select 271 workers who underwent occupational health examinations in Jiangmen Occupational Disease Control Institute from 2022 to 2023 as the research subjects according to the excessive hazard factors,and analyze the occupational health examination data. Results The excessive rate of noise detection point in the enterprise was 43.86%,the other testing index were all under the national occupational exposure limits(OELs). The abnormality rate of pure tone test was 60.15%,with a statistically significant difference in hearing abnormality rate between males and females( χ2=15.020,P<0.01). There was a statistically significant difference in hearing abnormality rate among males with different working years( χ2=14.139,P<0.01),while there was no statistically significant difference in hearing abnormality rate among females with different working years( χ2=4.959,P>0.05). There was no statistically significant difference in hearing abnormality rate among males exposed to different levels of noise intensity( χ2=0.047,P>0.05),while there was a statistically significant difference in hearing abnormality rate among females exposed to different levels of noise intensity( χ2=5.227,P<0.05). There was also a statistically significant difference in hearing abnormality rate among different positions( χ2=16.098,P<0.01). There was a statistically significant difference in hearing abnormality rate between the noise exposure group alone and the dust and noise exposure group ( χ2=7.540,P<0.01). Conclusion The hygiene conditions in the workplace of the magnetic material manufacturing enterprise and the health examination status of noise exposures are not optimistic. It was necessary to find the HACCP and take measures to protect the health of workers in the industry.

Key words: Magnetic material manufacturer, Noise, Hazard status, Hazard analysis and critical control point