摘要:

目的 了解西安市非医疗机构(不含涉密企业及宠物医院)的核技术应用及辐射防护现状,为相关主管部门制定监督规划和执行标准提供数据支持和参考依据。方法 针对2022—2024年西安市加速器、工业探伤、行包检测仪、核仪表、非密封源场所、密封源测井等主要的6类核技术应用项目采用分层抽样方式抽取部分放射工作场所依据相应标准开展防护检测,并对数据进行分析。结果 2022—2024年西安市应用核技术的非医疗机构呈现逐年递增的趋势,工业探伤应用是本地区主要非医疗应用项目。近3年西安市非医疗机构放射工作场所辐射水平均不超过相关标准规定的剂量限值。工业探伤工作场所辐射水平最高,为(2.14±8.41)μSv/h;加速器工作场所辐射水平最低,为(0.18±0.12)μSv/h;不同调查项目组检测结果相比,差异有统计学意义(H=37.658,P<0.05)。结论 正常运行情况下,西安市非医疗机构放射工作场所辐射水平整体处于较低水平,但个别关注点(如行包检测仪进出口、移动探伤场所、源容器外表面等)高于平均水平,故需要相关单位和主管部门提高防护意识,加强对辐射源的管理和对放射工作人员的职业健康管理。

关键词: 非医疗机构, 核技术, 周围剂量当量率, 表面污染水平, X射线装置, 密封源, 非密封源

Abstract:

Objective To understand the current situation of nuclear technology application and radiation protection in non-medical institutions(excluding confidential enterprises and pet hospitals) in Xi'an City,provide data support and theoretical basis for the relevant departments to formulate supervision plans and implementation standards. Methods A stratified sampling method was used to extract some radioactive workplaces in six main categories of nuclear technology application projects in Xi'an City from 2022 to 2024,such as accelerators,industrial flaw detection,baggage inspection instruments,nuclear instruments,unsealed source places,and sealed source logging. The protective testing was carried out according to corresponding standards,and the data were analyzed. Results The non-medical institutions using nuclear technology in Xi'an City were on the rise from 2022 to 2024. The industrial flaw detection was the main non-medical application item in this area. The radiation level in non-medical radiation workplaces in Xi'an City in the past three years did exceed the dose limit specified by the relevant standards. The radiation level in industrial radiographic inspection workplaces was the highest,which was (2.14±8.41)μSv/h,while the radiation level in accelerator workplaces was the lowest,which was (0.18±0.12)μSv/h. There was statistically significant difference in detection results among different survey items(H=37.658,P<0.05). Conclusions The radiation level in non-medical radiation workplaces of Xi'an City is generally at a low level under normal operation,but some points(such as the entrances and exits of baggage inspection equipment,mobile flaw detection site,and the outer surface of the source container) are higher than the average level. Therefore,the relevant units and competent departments need to enhance their awareness of protection,strengthen the management of radiation sources,and pay attention to the occupational health management of radiation workers.

Key words: Non-medical institution, Nuclear technology, Ambient dose equivalent rate, Surface contamination level, X-ray device, Sealed source, Non-sealed source